The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. You can find this in your power board. My pool pump and skimmer are on two different motors. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. did i do something incorrectly? The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. The timer quit after a nearby lightning strike. Or the switch can suffer wear over many years, and might not make solid contact. },
Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. #1. There's an issue with the wiring between the circuit breaker and the timer. After a power failure the timer clock can start up backwards, mine has done this several times. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. It is not warped in any way. I had a thunderstorm last night and my power went off for like 3 hours. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
12 Best Pool Pump Timers For Reducing Your Power Bill! Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. That way I could schedule the pump once again. Tighten down all brass screws securely, to hold all wires firmly in place. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. "
"image": {
If your Intermatic swimming pool timer has stopped working you will have to do something called troubleshooting. Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveller reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. Why do we stock so many pool parts? Did you try to flip the switch of the timeclock? Wired correctly, #10 wire, nothing. I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. Thanks for your help! The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. I just replaced my T101 timer 2 years ago.
975 Telegraph Rd #103, Santa Paula, CA 93060 | MLS# V1-15365 | Redfin "identifier": ""
"caption": "In The Swim Blog"
Reset the clock to the correct time. Should it still not work, I suspect a motor failure for the clock. Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. Then turn the breaker, that the time clock is connected to, off and back on again.
1100 Juanita St, Austin, TX 78704 | MLS #6354744 | Zillow Sometimes old power wires split or short-out. Does the tripper work on other areas of the clock, like near the off tripper? If you do have voltage either the timer isnt switching the power to the pump or theres an issue with the pump itself or the wiring between the pump and the timer. Also, does it sound like the power is not leaving the breaker?
Other than a couple of weeks, we have spent fifteen years manually turning on our pump. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. If I have to tell you which terminals to measure, you shouldnt be doing this! The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. Almost like it doesnt have the strength to click the timer on or off. Go for it, a little maintenance expense. how can I turn the time bar back down to the 6 oclock point so my timer will turn the lights on some how it is in the 2 oclock position an will not turn on automatically, Your email address will not be published. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Grab it, pull it towards you, move it around then place it back down. I have the same issue currently, and it makes no sense to me so far. I have an intermatic timer thats 2 years young. Ive seen it happen from lightning strikes, or insect infestation. I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input.
2425 Glenview Dr, HOLLISTER, CA 95023 | MLS# ML81913834 | Redfin That was probably what burned the plug. Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems. Is it Necessary? Look for any disconnected or damaged wires leading to the motor on the rear of the clock. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. Thanks Reid. Look to see if the clock is set to the correct time. Perhaps bad wiring or a bad breaker is to blame. I not sure if this is the best timer to use. Thanks. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. Here are some pictures. Now Im having to turn my pool pump on and off manually.
First time pool owner, Pool timer and trippers not working properly Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. Breakers go bad sometimes, after many years. Now ever sense I did that last week my timer wont shut off or turn on my pool pump.
My intermatic pool timer will not automatically turn on. I - JustAnswer Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. "width": "611",
How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4.
Pool Timer Not Turning ON or OFF!! Watch these tips and - YouTube i have a P1121 intermatic timer connected to a hayward above ground pool pump. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. Video of the Day Trippers },
Are the gears engaged, in the center, behind the dial? Hi Larry, if you can see the motor gears turning in the visual motor check, you may just need some lubrication added to the tripper mechanism. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. Hi Davy, If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. Just some ideas. I cant seem to find the exact replacement for this timer on the web and wanted to ask if you knew which intermatic pool timer model would match the one I have. Learn more about pool care and repair. The pool was running on a timer. Start with the easy checks. GFCI breakers trip at a very low threshold, doesnt take much. I used to run the pump for 8-9 hrs a day. No broken or loose wires visible. I have the Intermatic T103 autotimer on my pool. 3. Replace the gears if this is an issue. If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. These clocks determine when your pool pump turns on, and how long it runs. Some of the replacement motors make it past quality control with the incorrect gear setup. Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? If power is coming to the timer motor, you will clearly see the gears moving through the small window. Not sure if i need to check out the wiring, but it is a bit frustrating. 220V clocks have 5 terminals, 110V clocks have 3 terminals. You may need to adjust the meshing of the timer motor gear so it runs the clock. That should quiet it down. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. How can I fix this? And Ive noticed lately that the ON is not functioning all the time. Hi, new timer out of the box, 200V. Electrical Monke Aug 25, 2021 #22 It's broken. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . The capacitor for the motor may be bad. If so, is there power coming into the clock (on the line terminals)? Hi Sandra, does the on/off tab switch crisply, or softly? When I put the new one on, the trippers do not work. 4 Beds.
TORK Repair Questions & Solutions, Tips & Guides Page 2 - Fixya http://waterheatertimer.org/Tork-timers-and-manuals.html It is an ON tripper right? March 16, 2022 by WildRiverCountry. Why it always stop around 10pm by itself and not moving again? Ideally, the switch would be placed after the timeclock, not before. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Refer to the wiring diagram on the timer door for more information. As an Amazon Associate we earn from qualifying purchases. To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). Thanks in advance! If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time. There is a lot of water that is making the cover sink and I dont want to keep filling the pool with water trying to get the cover up/. Check out our online selection of new Intermatic timer clocks at InTheSwim.com! I unscrewed the clip and put it back on and its still doing the same thing. The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. Sometimes the trippers get loose or damaged. My Polaris booster pump ONLY turns on via the trippers. "@type": "Organization",
the ground wire? After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Sound right?
Types of Pool Timers & How They Work - Pool Research Or there could be a bad relay in the control panel, if you have ice cube style relays. Is it possible to do this by loosening the timer screw a bit? "publisher": {
Pull the timer out and turn it to the correct time. Timer dial is not turning Breaker OFF Turn ON Power Timer motor dead due to lightning Replace timer 3. Any help is greatly appreciated. So what would be the problem? Dead as a door nail. "dateModified": "1/10/2020",
If it doesnt, there could be an issue with the clock face or gears. I bought a new motor for mine after 20 years and learned about this the hard way. Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. Or fold the cover to one side if needed. Like # 8 09-16-07, 03:09 PM nap New Member Join Date: May 2006 Location: north Posts: 4,162 Clock not turning or making any sound. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. As it get cooler you can cut it down to 5 or 6 hr a day . "height": "219",
You off course will want to adjust one time pin at a time. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. Related Reading: Should You Get a Pool Pump Timer? A timer replacement would be required. Does this mean I need a new T104, or is there a replacement manual on/off switch? Put them back on and tighten them. I noticed that they had stopped. Hi, Davy, seeing lots of complaints here. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. the timer was directly plugged into a gfci and the pump directly into the timer.
Pool Timer Parts - Pool and Spa PartsFinder | In The Swim Was a good island when all the day trippers left One morning I noticed my pool didnt automatically turn off. The timer not working is for the pump. Also known as an RCD (residual current device) in Australia and the UK. To do this, pull the yellow-faced time dial (clockface) toward you.
Or be loose and not making good contact. Ive got a weak pump battery so every time the mechanism shuts off it looses time. Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. Hi Casey, perhaps the cord or wires are broken? I currently manually turn it on and off. Clock wont move, gear dont move at all. when the lever is in the off position the gears stop turningis this unit wired incorrectly, Natural goes to A Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. I think I have found it. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? Any advice on how to fix. It should sit down nicely. Now, Im going to order some additional timer clips. No matter what caused the issue, there is typically an easy fix! Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. Not sure if you still answer these but I have a weird one for you. I visually checked the clock motor and it was good. Pool Timer Not Turning ON or OFF!! Check that the breaker is firmly pushed onto the bar, and is not loose. If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. I have an intermatic T20004R and my timer is working because it is keeping the correct time. "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America.